Wind tunnel test maps airflow around airport terminal model

Share this news:

-- Researchers at Nanjing University of Aeronautics and Astronautics have mapped how air separates from an airport terminal model’s roof and circulates near its rear edge, identifying areas for closer examination in building wind-pressure tests.

The team from the university’s College of Civil Aviation used high-speed imaging and particle image velocimetry, or PIV, to measure airflow in a selected cross-section around a scale model. The experimental analysis identified separation at the windward eave, a shear layer extending downstream and an area of recirculating flow near the roof’s rear edge.

The findings connect several stages of airflow around the roof, providing a clearer picture of how the model’s shape redirects the approaching wind.

Velocity vectors overlaid on a smoke image show airflow around an airport terminal scale model during a wind tunnel test. Arrows indicate local flow direction, with pronounced changes near the roof and its rear edge. Source: Figure 2 of the supplied experimental article.

Airport terminal roofs often span large areas and have complex shapes. Understanding where air separates from those surfaces, and how the resulting flow develops downstream, helps researchers determine where to investigate wind-pressure effects.

The test took place in an atmospheric boundary-layer wind tunnel. The measurement setup combined a Revealer 2D2C PIV system with an S520M high-speed camera operating at 2,000 frames per second and a resolution of 2,560 by 1,920 pixels.

A high-frequency, double-pulse laser illuminated smoke particles in a thin sheet of light. The camera recorded their movement across a field of view measuring about 400 by 350 millimeters.

Software then compared pairs of images using cross-correlation to calculate particle displacement. Spatial calibration and the time interval between paired images converted those displacements into velocity vectors. The setup measured two velocity components within the illuminated plane, producing instantaneous and time-averaged views of the flow.

The velocity maps showed relatively consistent flow direction in the upper part of the measurement area. Closer to the roof and behind its rear edge, the arrows changed direction and length, revealing differences between the main airflow and the slower-moving air near the model.

Time-averaged analysis showed that air separated at the windward eave. A shear layer extended downstream between the main flow above and the lower-speed region near the roof. Near the rear edge, the analysis identified recirculation and asymmetric vortical structures.

Obtaining usable images required adjustments to both the smoke supply and the model.

Maintaining a suitable smoke concentration was difficult in the open-circuit wind tunnel. The team used smoke cakes and a honeycomb device to improve smoke distribution through the measurement area.

Reflections from the 3D-printed model also caused local overexposure. Researchers coated its surface with matte black paint and adjusted the laser-sheet illumination to reduce glare and interference from the model blocking the light.

Those measures addressed practical obstacles that affect PIV measurements around complex building shapes: tracer coverage, image contrast and illumination of the target area.

The report identifies the windward eave and rear-edge recirculation region as priorities for follow-up tests combining velocity measurements with synchronized surface-pressure measurements. That approach would allow researchers to examine the relationship between changes in the surrounding airflow and pressure variations on the roof.

Contact Info:
Name: Harrison Shawn
Email: Send Email
Organization: HF Agile Device Co., Ltd.
Website: http://www.revealerhighspeed.com

Release ID: 89211047

CONTACT ISSUER
Name: Harrison Shawn
Email: Send Email
Organization: HF Agile Device Co., Ltd.
REVIEWED BY
Editor Profile Picture
This content is reviewed by our News Editor, Hui Wong.

If you need any help with this piece of content, please contact us through our contact form
SUBSCRIBE FOR MORE